The maximum operating temperature range for the M48Z128-70PM1 is -40°C to +85°C.
The M48Z128-70PM1 has an internal POR circuit that resets the device when the power supply voltage (VCC) rises above 1.5V. No external POR circuit is required.
The recommended clock frequency for the M48Z128-70PM1 is up to 1 MHz, but it can operate up to 2 MHz with some limitations.
To ensure data retention, the VCC pin must be maintained above 1.5V during power-down. If VCC falls below 1.5V, the device will enter a low-power state, and data may be lost.
Yes, the M48Z128-70PM1 is suitable for BBR applications. It has a low standby current and can retain data for up to 10 years with a 3V lithium battery.