The M29W128FH70ZA6E has a minimum of 100,000 erase cycles per sector, and a total of 1,000,000 erase cycles for the entire device.
The HOLD# signal should be kept low during read and write operations to ensure that the device is not put into a hold state. If the HOLD# signal is asserted during a read or write operation, the device will pause the operation and enter a hold state.
The recommended power-up sequence is to apply VCC first, followed by VPP (if used), and then the clock signal. This ensures that the device is properly initialized and ready for operation.
The write protection mechanism can be enabled or disabled using the WP# signal. When WP# is low, the device is write-protected, and when WP# is high, the device is not write-protected. Additionally, the device has a software-based write protection mechanism that can be enabled or disabled using specific commands.
The M29W128FH70ZA6E has a maximum operating frequency of 70 MHz.