The recommended operating voltage range for the M27C4001-12F1 is 4.5V to 5.5V.
The power-up sequence should be VCC first, then OE# and CE#. For power-down, the sequence should be CE# and OE# first, then VCC.
The maximum clock frequency supported by the M27C4001-12F1 is 12 MHz.
To ensure data retention, the VCC must be reduced to 2V or less within 10 ms of power-down, and the CE# and OE# pins must be in the inactive state.
The WP# (Write Protect) pin is used to prevent accidental writes to the device. When WP# is low, the device is in write-protect mode, and no writes are allowed.