The recommended storage temperature range for the M24128-BFMH6TG is -40°C to +125°C.
To prevent damage, it is recommended to use a soldering iron with a temperature below 260°C and a soldering time of less than 10 seconds. Additionally, the device should be handled by the package body, not the pins.
The maximum operating frequency of the M24128-BFMH6TG is 10 MHz.
To ensure data retention, the device should be powered within the recommended voltage range (2.5V to 5.5V) and the storage temperature should be within the recommended range (-40°C to +125°C).
The typical standby current of the M24128-BFMH6TG is 1 μA.