The recommended termination impedance is 1 kΩ to ensure proper signal integrity and minimize reflections.
While the M100F-010.0M is rated for industrial temperature range (-40°C to 85°C), it's recommended to derate the frequency stability and consider additional thermal management for extreme temperature applications.
To ensure reliable startup, ensure a stable power supply, add a 10-100 nF decoupling capacitor near the oscillator, and consider adding a pull-up resistor (1 kΩ - 10 kΩ) on the output to prevent oscillations.
The M100F-010.0M can drive up to 15 pF of capacitance load, but it's recommended to keep the load capacitance below 10 pF to maintain signal integrity and minimize ringing.
Yes, the M100F-010.0M can be used in designs with multiple power domains, but ensure proper power sequencing and isolation to prevent damage or malfunction.