The maximum operating temperature range for the LTC4211CMS8 is -40°C to 125°C.
To ensure reliable hot swap operation, make sure to follow the recommended layout and component selection guidelines, and use a suitable hot swap controller like the LTC4211CMS8. Also, ensure that the power supply is stable and within the recommended operating range.
The maximum current rating for the LTC4211CMS8 is 10A. However, the actual current rating may vary depending on the application and operating conditions.
The overcurrent threshold for the LTC4211CMS8 can be programmed using an external resistor connected between the OCSET pin and GND. The threshold is calculated using the formula: I_OC = 0.1V / R_OCSET.
The FAULT pin on the LTC4211CMS8 is an open-drain output that indicates a fault condition, such as overcurrent, overvoltage, or undervoltage. It can be used to trigger an interrupt or shutdown the system in case of a fault.