The maximum input voltage that can be applied to the LTC4059 is 18V, but it's recommended to keep it below 15V for reliable operation.
To ensure proper power-up and configuration, follow the recommended power-up sequence: VCC, then EN, then VIN. Also, make sure to tie the EN pin high to enable the device.
The TRK/SS pin is used for tracking or soft-start functionality. Connect a capacitor from TRK/SS to GND to set the soft-start time. A larger capacitor value will result in a slower soft-start.
Choose an inductor with a high saturation current rating, low DC resistance, and a suitable inductance value (e.g., 1-10uH). Also, consider the inductor's physical size, cost, and temperature rating.
Keep the input and output capacitors close to the IC, and use a solid ground plane to reduce noise and improve thermal performance. Ensure good airflow around the device, and consider using a heat sink if necessary.