LTC2145IUP-12#TRPBF datasheet
by Linear Technology
LTC2145 - IC 2-CH 12-BIT PROPRIETARY METHOD ADC, PARALLEL ACCESS, PQCC64, 9 X 9 MM, LEAD FREE, PLASTIC, MO-220WNJR-5, QFN-64, Analog to Digital Converter
The maximum power dissipation of the LTC2145IUP-12 is dependent on the operating temperature and the thermal resistance of the package. According to the datasheet, the maximum power dissipation is 1.4W at 25°C with a thermal resistance of 57.1°C/W. However, it's recommended to derate the power dissipation to ensure reliable operation.
To optimize the layout for the LTC2145IUP-12, it's essential to follow good high-frequency PCB design practices. This includes using a solid ground plane, minimizing trace lengths and widths, and keeping sensitive nodes away from noisy areas. Additionally, ensure that the input and output capacitors are placed close to the device and that the thermal pad is properly connected to a heat sink or thermal relief.
The recommended input and output capacitance for the LTC2145IUP-12 is 10uF to 22uF, with an ESR of less than 100mΩ. However, the optimal capacitance value may vary depending on the specific application and operating conditions. It's recommended to experiment with different capacitance values to achieve the best performance.
To ensure the LTC2145IUP-12 is stable and doesn't oscillate, it's essential to follow the recommended layout and component selection guidelines. This includes using a stable input voltage, selecting the correct output capacitance, and ensuring that the device is properly decoupled. Additionally, it's recommended to add a small series resistor (e.g., 1Ω to 10Ω) between the output and the load to prevent oscillation.
The maximum operating temperature range for the LTC2145IUP-12 is -40°C to 125°C. However, the device's performance and reliability may degrade at extreme temperatures. It's recommended to operate the device within the recommended temperature range to ensure optimal performance and reliability.