The maximum operating temperature range for the LPC1346FHN33,551 is -40°C to +85°C.
The clock settings for the LPC1346FHN33,551 can be configured using the Clock Generation Unit (CGU) registers. The CGU provides a flexible clock generation system that allows the user to configure the clock sources, dividers, and multipliers to generate the desired clock frequencies.
The maximum current consumption of the LPC1346FHN33,551 depends on the operating frequency and voltage. According to the datasheet, the maximum current consumption is approximately 130 mA at 48 MHz and 3.3V.
The LPC1346FHN33,551 has a USB 2.0 full-speed device controller that can be used to implement USB device functionality. The USB interface can be configured using the USB registers and the USB library provided by NXP Semiconductors.
The maximum flash memory endurance of the LPC1346FHN33,551 is 100,000 program/erase cycles.