The maximum operating temperature range for the LNK604DG is -40°C to 150°C, but the device is typically specified for operation up to 125°C.
To ensure proper biasing for startup, make sure the VCC pin is connected to a stable voltage source (typically 12V to 18V) and the EN/UV pin is pulled high (above 2.5V) to enable the device.
For optimal performance, follow Power Integrations' recommended layout guidelines, including keeping the high-voltage nodes (e.g., DRAIN, SOURCE) away from low-voltage nodes (e.g., VCC, EN/UV), using a solid ground plane, and minimizing trace lengths and widths.
Choose a transformer with a turns ratio that matches the desired output voltage, and ensure the transformer's primary inductance is within the recommended range (typically 1.5mH to 3.5mH) to achieve optimal performance and efficiency.
To minimize EMI and noise, use a common-mode choke, add a Y-capacitor between the primary and secondary windings, and ensure proper PCB layout and grounding. Additionally, consider using a shielded transformer and adding a snubber circuit to reduce ringing.