The recommended power-on sequence is to apply VDD first, followed by VDDIO, and then the clock signal. This ensures proper initialization of the device.
To configure the LIS352AR for low-power mode, set the LPEN bit in the CTRL_REG1 register to 1. This reduces the current consumption to approximately 10 μA.
The LIS352AR has a maximum acceleration range of ±2g, ±4g, ±8g, or ±16g, depending on the range selection made through the CTRL_REG2 register.
The sensitivity of the LIS352AR can be adjusted by changing the full-scale range through the CTRL_REG2 register. A higher range setting reduces the sensitivity, while a lower range setting increases the sensitivity.
The SELFTEST bit enables a self-test mode that applies a known acceleration to the sensor, allowing the user to verify the device's functionality and calibration.