XP Power recommends a PCB layout with a large copper area for heat dissipation, and a minimum of 2oz copper thickness. A thermal via array under the module is also recommended.
To ensure reliable start-up, XP Power recommends a soft-start circuit or a ramp-up of the input voltage to prevent inrush currents. Additionally, a minimum input capacitance of 10uF is recommended.
The maximum allowed capacitance on the output is 220uF. Exceeding this value may affect the stability of the converter.
Yes, the JCK1524D15 can be used in a redundant configuration. However, XP Power recommends using a diode orifice or a redundancy module to ensure proper operation and to prevent back-feeding of power.
The recommended input fuse rating is 2A slow-blow. This ensures that the fuse does not trip during normal operation, but still provides protection against fault conditions.