The recommended operating temperature range for ISP1160BD/01 is -40°C to +85°C, as specified in the datasheet. However, it's essential to note that the device can operate at temperatures up to +100°C for short periods, but this may affect its reliability and lifespan.
To ensure reliable data transfer over the USB interface, it's crucial to follow the USB specification guidelines, use proper shielding and grounding, and implement error detection and correction mechanisms in your firmware. Additionally, ensure that the device is properly powered and that the USB bus is not overloaded.
The maximum cable length supported by ISP1160BD/01 is 3 meters (10 feet) for full-speed devices and 1.5 meters (5 feet) for low-speed devices, as specified in the USB 1.1 specification. However, the actual cable length may vary depending on the cable quality, noise levels, and other environmental factors.
To handle suspend and resume operations, you need to implement the necessary logic in your firmware to detect and respond to USB suspend and resume signals. This typically involves saving the device state, powering down unnecessary components, and restoring the device state when resuming. Consult the datasheet and USB specification for more information.
The ISP1160BD/01 has several power management options, including dynamic voltage scaling, clock gating, and power-down modes. These features can be controlled through registers and can help reduce power consumption and heat generation in the device.