The maximum voltage that can be applied to the input pins is ±40V, but it's recommended to keep it within ±20V for optimal performance.
To ensure accurate current measurements, make sure to use a sense resistor with a low temperature coefficient, keep the sense resistor close to the INA301, and use a low-noise power supply.
The INA301's accuracy can be affected by temperature changes. The device has a specified temperature range of -40°C to 125°C, and the accuracy may degrade at extreme temperatures.
Yes, but be aware that high-impedance sense resistors can increase the noise and reduce the accuracy of the current measurement. It's recommended to use a low-impedance sense resistor (<100Ω) for optimal performance.
You can use a low-pass filter or a capacitor in parallel with the sense resistor to filter out noise and ripple. Additionally, using a high-quality power supply and proper PCB layout can also help reduce noise.