The maximum capacitance load for the ICH5024S05 is 10uF. Exceeding this value may affect the stability of the output voltage.
While the ICH5024S05 has a rated operating temperature range of -40°C to 85°C, it's recommended to derate the output power by 2.5% per degree above 60°C to ensure reliable operation.
To ensure EMC, follow proper PCB layout and design guidelines, use a metal enclosure, and add external filtering components (e.g., common-mode chokes, capacitors) as needed to meet relevant EMC standards.
While the datasheet specifies a minimum input voltage of 3.3V, it's recommended to operate the ICH5024S05 with an input voltage between 4.5V and 5.5V for optimal performance and reliability.
Yes, you can parallel multiple ICH5024S05 devices to increase output current, but ensure that each device has its own input capacitor and that the output capacitors are properly sized to handle the increased current.