Broadcom recommends a PCB layout with a solid ground plane, minimal track length, and a 50-ohm transmission line for the output stage to ensure optimal performance and minimize electromagnetic interference (EMI).
To ensure reliable operation in high-temperature environments, it is essential to follow proper thermal management practices, such as providing adequate heat sinking, using a thermally conductive PCB material, and keeping the junction temperature below 125°C.
The maximum allowable voltage on the VCC pin of HCPL-7723 is 5.5V. Exceeding this voltage can cause permanent damage to the device.
Yes, HCPL-7723 is designed for galvanic isolation and can be used in applications requiring electrical isolation between the input and output stages.
The typical propagation delay of HCPL-7723 is around 10 ns, but this can vary depending on the specific application and operating conditions.