Crouzet recommends a minimum spacing of 2mm between the relay and other components on the PCB, and a minimum of 5mm between the relay and the PCB edge. A recommended PCB layout is available in the Crouzet application note AN-REL-001.
To ensure reliable operation in high-vibration environments, Crouzet recommends using a relay socket or a relay holder with a secure screw or clip mounting system. Additionally, the PCB should be designed to minimize flexure and ensure the relay is properly secured.
The GNR30DCZH relay can withstand a maximum surge current of 100A for 10ms, as specified in the Crouzet application note AN-REL-002.
Yes, the GNR30DCZH relay is designed to meet the requirements of safety standards such as IEC 61508 and EN 50155. However, it is essential to follow the guidelines and recommendations provided in the Crouzet safety manual and to consult with a safety expert to ensure the relay is used in a safe and compliant manner.
Crouzet recommends derating the relay's current rating by 1.5% per degree Celsius above 40°C, as specified in the datasheet. For example, at 60°C, the relay's current rating should be derated by 30%.