Triad Magnetics recommends a symmetrical PCB layout with the transformer centered on the board, and keeping the primary and secondary windings as close together as possible to minimize leakage inductance.
Triad Magnetics recommends providing adequate airflow around the transformer, using a heat sink if necessary, and ensuring that the ambient temperature does not exceed 40°C (104°F).
The maximum voltage rating for the primary winding is 800VRMS, and for the secondary winding is 24VRMS. Exceeding these ratings may result in transformer failure.
Yes, the FS24-800-C2 is suitable for switching power supply applications, but Triad Magnetics recommends ensuring that the switching frequency does not exceed 100 kHz to avoid core saturation.
Triad Magnetics recommends a minimum creepage distance of 4.5 mm (0.177 in) between the primary and secondary windings to ensure electrical isolation.