The recommended operating temperature range for the F12-1000-C2 is -40°C to 125°C, with a maximum storage temperature of 150°C.
While the F12-1000-C2 is designed for 1000Vrms isolation, it is not recommended for high-voltage applications above 1500Vrms. For higher voltage applications, consider using a transformer with a higher isolation voltage rating.
To ensure proper creepage and clearance distances, follow the guidelines in the relevant safety standards (e.g., IEC 60950-1 or UL 60950-1) and maintain a minimum creepage distance of 4.5mm and clearance distance of 3.2mm between the primary and secondary windings.
The F12-1000-C2 is designed for Class I applications, but it can be used in Class II or Class III applications with proper design and certification. Consult with a qualified engineer or safety expert to ensure compliance with relevant safety standards.
To minimize electromagnetic interference (EMI) and ensure proper operation, follow good PCB layout practices, such as keeping the primary and secondary windings separate, using a ground plane, and maintaining a minimum spacing of 1.5mm between the transformer and other components.