The recommended operating voltage range for the DS24B33Q+T&R is 2.7V to 5.5V.
To ensure reliable communication, ensure that the 1-Wire bus is properly terminated, use a pull-up resistor on the DQ pin, and follow the 1-Wire protocol timing specifications.
The maximum number of devices that can be connected to a single 1-Wire bus is limited by the bus capacitance and the pull-up resistor value, but typically ranges from 10 to 100 devices.
Implement error detection and correction mechanisms, such as CRC checks and retries, to ensure reliable data transfer over the 1-Wire bus.
The typical current consumption of the DS24B33Q+T&R is 1mA in active mode and 1μA in standby mode.