The recommended operating voltage range for the DS2431 is 2.7V to 5.5V.
To ensure reliable communication, ensure that the 1-Wire bus is properly terminated, and the master device is configured to provide a strong pull-up on the bus. Also, ensure that the DS2431 is properly powered and that the voltage supply is stable.
The maximum number of DS2431 devices that can be connected to a single 1-Wire bus is 256, due to the 8-bit ROM address space.
Implement error detection and correction mechanisms, such as CRC checks and retries, to handle errors during data transfer over the 1-Wire bus.
The typical current consumption of the DS2431 is 1.5mA during active operation, and 1μA in standby mode.