The recommended operating temperature range for the DS1390U-33+T&R is -40°C to +85°C.
To ensure the accuracy of the RTC, use a high-quality crystal oscillator and follow the recommended crystal specifications. Also, ensure that the device is properly calibrated during manufacturing and that the clock is regularly synchronized with an external time source.
The maximum current consumption of the DS1390U-33+T&R is 1.5mA at 5V supply voltage.
The DS1390U-33+T&R can be interfaced with a microcontroller using a 3-wire serial interface (SCL, SDA, and RST). The microcontroller can communicate with the DS1390U-33+T&R using I2C protocol.
The RST pin is an active-low reset input that resets the device when pulled low. It is used to reset the device and restore its default settings.