The recommended power-up sequence is to apply VCC first, followed by VBAT. This ensures that the internal registers are properly initialized.
The oscillator startup time is typically around 2-3 milliseconds. You can add a delay or use a reset signal to ensure that the oscillator is stable before accessing the device.
The RST pin is an active-low reset input that resets the device when pulled low. It can be used to reset the device in case of a fault or to initialize the device during power-up.
To ensure a stable clock output, make sure to add a load capacitor (CL) between the X1 and X2 pins, and use a suitable crystal oscillator with a frequency of 32.768 kHz.
The maximum frequency for the clock output is 1 Hz to 64 kHz, depending on the configuration of the device.