The recommended power-up sequence is to apply VCC first, followed by AVCC, and then the digital supply (VDD). This ensures that the analog and digital sections of the device are powered up correctly.
To ensure accurate output voltage, it is essential to use a high-quality reference voltage source, ensure proper PCB layout and decoupling, and follow the recommended output filtering and buffering configurations.
The maximum output current capability of the DAC908EG4 is 10 mA per channel. Exceeding this limit can cause damage to the device or affect its performance.
During power-down or reset, it is recommended to tri-state the digital interface (SCLK, SDIN, and SYNC) to prevent any unwanted data transmission or reception.
The recommended clock frequency range for the DAC908EG4's digital interface is 10 kHz to 50 MHz. Operating outside this range may affect the device's performance or cause errors.