The recommended power-up sequence is to apply VCC first, followed by AVCC, and then the digital supply (DVCC). This ensures proper device operation and prevents latch-up.
To ensure accurate voltage output, it's essential to use a high-precision voltage reference (VREF) and to decouple the analog supply (AVCC) with a 10uF capacitor. Additionally, ensure the output load is within the recommended range (1kΩ to 10kΩ).
The maximum output current of the DAC8718 is 5mA. Exceeding this limit may cause device damage or affect output accuracy.
During power-down or reset, it's recommended to tri-state the digital interface (SDI, SCK, and CS) to prevent unwanted data transmission or device malfunction.
The internal voltage reference (VREF) provides a stable voltage reference for the DAC, ensuring accurate output voltage. It can also be used as a reference for other devices in the system.