TI recommends a 4-layer PCB with a solid ground plane, and to keep the analog and digital signals separate. Use short, direct traces for the analog output, and avoid crossing digital signals over the analog output traces.
To configure the DAC7760IRHAR for bipolar output voltage operation, connect the VREF pin to a voltage reference, and set the BIPOLAR bit in the control register to '1'. Ensure the output voltage range is within the specified limits.
Power up the DAC7760IRHAR in the following sequence: VCC, AVCC, DVCC, and then the digital inputs. Ensure all power supplies are stable before applying digital inputs.
The internal voltage reference can be used, but it may not provide the best accuracy. Using an external voltage reference can improve accuracy, but ensure it is stable and has a low noise output. Consult the datasheet for specific requirements.
The DAC7760IRHAR has a maximum junction temperature of 150°C. Ensure good airflow, use a heat sink if necessary, and avoid blocking airflow around the device. Consult the thermal design guidelines in the datasheet.