The CY62128EV30LL-45ZAXI can operate from -40°C to 85°C.
The device has a built-in power-on reset circuit, and it is recommended to power up the device slowly (less than 10 ms) to ensure proper initialization. During power-down, the device should be powered down slowly as well to prevent data loss.
The maximum clock frequency for the CY62128EV30LL-45ZAXI is 45 MHz.
The CY62128EV30LL-45ZAXI is a synchronous SRAM that can be interfaced with a microcontroller or processor using a synchronous interface. The device requires a clock signal, chip select, and address and data buses to operate.
The CY62128EV30LL-45ZAXI has a latency of 2 clock cycles for read and write operations.