The recommended operating voltage range for the CY23S05SXC-1H is 2.97V to 3.63V.
To ensure reliable operation in high-temperature environments, it is recommended to follow proper thermal management practices, such as providing adequate heat sinking and airflow, and ensuring that the device is operated within its specified temperature range.
The CY23S05SXC-1H supports clock frequencies up to 25 MHz.
The CY23S05SXC-1H can be clocked using an external clock source, such as a crystal oscillator or a clock generator IC. The clock signal should be connected to the XIN pin, and the clock frequency should be within the specified range.
The RST pin is an active-low reset input that can be used to reset the device. When the RST pin is driven low, the device will reset and all registers will be cleared.