The recommended operating voltage range for the CY2304NZZC-1 is 3.0V to 3.6V.
The clock output frequency of the CY2304NZZC-1 can be configured by selecting the appropriate values for the MF and M pins. Refer to the datasheet for the frequency selection table.
The maximum clock frequency that the CY2304NZZC-1 can support is 133 MHz.
Yes, the CY2304NZZC-1 can be used as a clock buffer. It has a low-skew clock distribution architecture that makes it suitable for buffering and distributing clock signals.
The typical power consumption of the CY2304NZZC-1 is around 20mA at 3.3V and 25°C.