The maximum operating temperature range for the CSD18563Q5A is -40°C to 150°C.
To ensure proper biasing, connect the gate to a voltage source through a resistor, and connect the source to a voltage source or ground through a resistor. Refer to the datasheet for specific biasing recommendations.
To minimize parasitic inductance and capacitance, use a compact PCB layout with short, wide traces, and place the device close to the power source. Avoid using vias under the device, and use a solid ground plane to reduce inductance.
Use a voltage regulator or a zener diode to limit the voltage, and add a current-limiting resistor or a fuse to prevent overcurrent conditions. Also, consider adding a TVS diode for ESD protection.
The recommended gate drive voltage for the CSD18563Q5A is between 4.5V and 15V, with a typical value of 10V.