The recommended operating frequency range for the CMT908-V2 is 50 kHz to 500 kHz, although it can operate up to 1 MHz with reduced performance.
Proper thermal management can be achieved by providing adequate airflow, using a heat sink, and ensuring that the transformer is not operated above its maximum temperature rating of 130°C.
The maximum voltage rating for the CMT908-V2 is 1500 VRMS, although it's recommended to operate at a maximum of 1200 VRMS for optimal performance and reliability.
Yes, the CMT908-V2 can be used in a push-pull configuration, but it's essential to ensure that the transformer is properly biased and that the drive circuitry is designed to handle the resulting voltage and current stresses.
To minimize leakage inductance, ensure that the transformer is properly wound and that the primary and secondary windings are tightly coupled. Additionally, using a Faraday shield or a shielded bobbin can help reduce leakage inductance.