The recommended power-up sequence is to apply VCC first, followed by VCC_IO, and then the clock signal. This ensures proper initialization and prevents damage to the device.
The CDCV850IDGG can be configured for a specific clock frequency by setting the appropriate values for the DIV_SEL[2:0] and CLK_SEL[1:0] pins. Refer to the datasheet for the specific configuration for your desired clock frequency.
The CDCV850IDGG supports clock frequencies up to 850 MHz. However, the maximum frequency may vary depending on the specific application and board design.
The CDCV850IDGG is designed to operate with a 1.8V voltage supply. While it may be possible to use it with a different voltage supply, it is not recommended as it may affect the device's performance and reliability.
Proper thermal management is crucial for the CDCV850IDGG. Ensure good airflow around the device, use a heat sink if necessary, and follow the recommended thermal design guidelines in the datasheet.