The CD74HCT164E can handle clock frequencies up to 30 MHz.
The CD74HCT164E requires a power supply voltage (VCC) of 4.5V to 5.5V, and it is recommended to use a decoupling capacitor of 0.1uF to 1uF between VCC and GND to ensure proper power supply decoupling.
The CD74HCT164E can tolerate input voltages up to 7V without damage, but it is recommended to keep input voltages within the specified operating range of 0V to VCC to ensure proper operation.
The CLR input should be tied to VCC through a pull-up resistor (e.g., 1kΩ) to ensure that the device is not inadvertently reset. When CLR is low, the device is reset, and all outputs are set to low.
The propagation delay of the CD74HCT164E is typically around 10ns to 20ns, depending on the operating conditions and load capacitance.