The CD74HC75E can handle clock frequencies up to 10 MHz.
The CD74HC75E requires a single 2V to 6V power supply, and it's recommended to use a decoupling capacitor of 0.1uF to 1uF between VCC and GND to ensure proper power supply decoupling.
The CD74HC75E can tolerate input voltages up to 6.5V, but it's recommended to keep input voltages within the recommended operating range of 2V to 6V to ensure proper operation.
The CD74HC75E has an asynchronous reset input (MR) that can be used to reset the device. To reset the device, pull the MR input low for at least 10ns.
The propagation delay of the CD74HC75E is typically around 10ns to 20ns, depending on the operating frequency and voltage.