The CD74HC4020E can handle clock frequencies up to 25 MHz.
The CD74HC4020E requires a single 2-V to 6-V power supply, and it's recommended to use a decoupling capacitor of 0.1 μF to 1 μF between VCC and GND to ensure proper power supply decoupling.
The CD74HC4020E can tolerate input voltages up to 6.5 V, but it's recommended to keep input voltages within the recommended operating conditions of 2 V to 6 V to ensure proper operation.
The asynchronous reset input (MR) should be tied to VCC through a pull-up resistor (e.g., 1 kΩ) to ensure that the counter is properly reset when the input is high. When the input is low, the counter will reset.
The propagation delay of the CD74HC4020E is typically around 15 ns, but it can vary depending on the operating conditions and the specific application.