The recommended operating voltage range for CD74HC374M96E4 is 2V to 6V, with a typical voltage of 5V.
It is recommended to power up the VCC pin before the input signals, and power down the VCC pin after the input signals. This ensures that the device is properly initialized and avoids any potential latch-up conditions.
The maximum clock frequency that CD74HC374M96E4 can handle is 25 MHz, but this can vary depending on the operating voltage and temperature.
It is recommended to use a pull-up or pull-down resistor on the output pins to ensure that they are not floating during power-up or power-down. Additionally, consider using a reset signal to initialize the device after power-up.
Yes, CD74HC374M96E4 can be used in a 3.3V system, but the output voltage levels may not be compatible with 3.3V logic. Consider using a level translator or voltage regulator to ensure compatibility.