The recommended operating voltage range for the CD74AC86M96 is 2.0V to 6.0V, with a typical voltage of 5.0V.
The input voltage thresholds for the CD74AC86M96 are typically 0.5V to 1.5V for low input and 3.5V to 5.5V for high input. Ensure that your input signals meet these thresholds to ensure proper operation.
The maximum clock frequency supported by the CD74AC86M96 is 30MHz, but this can vary depending on the operating voltage and load conditions.
To ensure proper power sequencing, apply power to the VCC pin before applying any input signals. Also, ensure that the power supply is stable and within the recommended operating range before applying input signals.
The typical propagation delay for the CD74AC86M96 is around 10ns to 15ns, but this can vary depending on the operating voltage, temperature, and load conditions.