The recommended operating voltage range for the CD4724BE is 4.5V to 15.5V, although the device can operate with a minimum voltage of 3V.
To minimize power consumption, ensure that the input voltage (VCC) is reduced to 0V, and all input signals are at a logic low level. This will put the device in a low-power standby mode.
The maximum frequency of operation for the CD4724BE is 10 MHz, although the device can operate at frequencies up to 20 MHz with reduced voltage and load capacitance.
To handle thermal considerations, ensure good thermal conductivity between the device and the PCB, and consider using a heat sink or thermal pad to dissipate heat. The maximum junction temperature is 150°C.
To minimize noise and ensure proper operation, use a ground plane, keep signal traces short and away from power traces, and use bypass capacitors to decouple the power supply.