The CD4010BE can handle clock frequencies up to 10 MHz, but it's recommended to operate it at a maximum frequency of 5 MHz for reliable operation.
The CD4010BE requires a single 5V power supply, and it's recommended to use a decoupling capacitor (e.g., 0.1uF) between VCC and GND to reduce noise and ensure stable operation.
The CD4010BE can tolerate input voltages up to 15V, but it's recommended to operate it within the specified voltage range of 4.5V to 5.5V for reliable operation.
The CD4010BE has open-drain outputs, which means they can sink current but not source current. You may need to add pull-up resistors to the outputs to ensure proper operation.
The CD4010BE is rated for operation up to 125°C, but its performance may degrade at high temperatures. It's recommended to operate it within the specified temperature range of -40°C to 85°C for reliable operation.