The BSS123 can operate safely between -55°C to 150°C, but the recommended operating temperature range is -40°C to 125°C.
To ensure proper biasing, connect the gate to a voltage source through a resistor (e.g., 1 kΩ) and the source to ground. The drain should be connected to a load or a voltage source.
The maximum continuous drain current (ID) for the BSS123 is 1.5 A, and the pulsed drain current (IDM) is 3 A.
Handle the BSS123 by the body, avoid touching the pins, and use an anti-static wrist strap or mat. Store the device in an anti-static bag or wrap it in anti-static material.
Yes, the BSS123 can be used as a switch in high-frequency circuits due to its low input capacitance (Ci) of 10 pF and low output capacitance (Co) of 20 pF.