The BSS123 can operate from -55°C to 150°C, but the recommended operating temperature range is -40°C to 125°C.
To ensure proper biasing, the gate-source voltage (Vgs) should be between 2V and 4V, and the drain-source voltage (Vds) should be between 1V and 20V.
The maximum continuous drain current (Id) rating for the BSS123 is 1A, but it can handle up to 2A for short pulses.
To protect the BSS123 from ESD, use proper handling and storage procedures, such as using anti-static bags, wrist straps, and mats, and ensure that the device is properly grounded during assembly.
Yes, the BSS123 can be used as a switch in high-frequency applications up to 100 kHz, but it's essential to consider the device's switching characteristics, such as rise and fall times, and ensure proper PCB layout and decoupling to minimize ringing and oscillations.