The maximum operating temperature range for the AUIPS7111S is -40°C to 150°C.
To ensure proper biasing, connect the VCC pin to a stable 5V power supply, and the EN pin to a logic-level signal (e.g., 3.3V or 5V) to enable the device.
For optimal PCB layout, place the AUIPS7111S near the power source, use a solid ground plane, and keep the input and output traces short and separate to minimize EMI. Also, ensure good thermal conduction by using a thermal pad or heat sink.
Use a voltage regulator or a transient voltage suppressor (TVS) to protect the AUIPS7111S from overvoltage conditions. For undervoltage protection, use a voltage supervisor or a reset IC to monitor the input voltage and reset the device if it falls below a certain threshold.
The recommended input capacitor value for the AUIPS7111S is 10uF to 22uF, with an X5R or X7R dielectric, to ensure stable operation and minimize input ripple.