The recommended operating temperature range for the AM26S10CD is -40°C to 85°C. However, it's essential to note that the device can operate up to 125°C for short periods, but this may affect its reliability and lifespan.
To ensure proper power-on and power-off, it's recommended to follow a specific sequence: VCC should be applied before VBB, and VCC should be removed before VBB. Additionally, the power supply should be stable and free of noise to prevent damage to the device.
The maximum allowed voltage on the VBB pin is 15V. Exceeding this voltage may damage the device. It's essential to ensure that the voltage on VBB is within the recommended range to maintain the device's reliability and performance.
To handle ESD protection, it's recommended to follow proper handling and storage procedures, such as using anti-static wrist straps, mats, and bags. Additionally, the device should be soldered and assembled in an ESD-controlled environment to prevent damage during manufacturing.
The recommended layout and routing for the AM26S10CD involves keeping the power supply lines (VCC and VBB) separate from the signal lines, using a solid ground plane, and minimizing the length of the signal lines to reduce noise and interference.