    Part Img ADS7842EB/1K datasheet by Texas Instruments

    • 12-Bit, 4-Channel Parallel Output Sampling Analog-to-Digital Converter
    • Original
    • Yes
    • Yes
    • Active
    • EAR99
    • 8542.39.00.01
    • 8542.39.00.00
    • Powered by Findchips Logo Findchips

    ADS7842EB/1K datasheet preview

    ADS7842EB/1K Frequently Asked Questions (FAQs)

    • The recommended power-up sequence is to apply VCC first, followed by VREF, and then the clock signal. This ensures proper initialization of the device.
    • The BUSY signal goes high during conversion and remains high until the conversion is complete. The host should wait for BUSY to go low before accessing the data.
    • The maximum frequency of the clock signal is 3.25 MHz. Exceeding this frequency may result in incorrect conversions or device malfunction.
    • Calibration involves adjusting the internal offset and gain of the device. TI provides a calibration procedure in the datasheet, which involves applying a known input voltage and adjusting the offset and gain registers accordingly.
    • The ADS7842's performance is affected by temperature, with changes in offset, gain, and noise floor. TI provides temperature coefficients in the datasheet to help engineers compensate for these effects.