The recommended input impedance for the ADC128S052 is 1 kΩ to 10 kΩ. This ensures proper signal attenuation and prevents signal reflections.
The ADC128S052 requires a clock signal between 1 MHz and 50 MHz. It's recommended to use a clock signal with low jitter and a stable frequency to ensure accurate conversions.
The VREF pin sets the reference voltage for the ADC. It's recommended to connect VREF to a stable voltage source between 1.2 V and 3.3 V to ensure accurate conversions.
The ADC128S052 has a power-on reset (POR) sequence that requires a specific sequence of voltage application. Ensure that VDD is applied before VREF and that the clock signal is stable before starting conversions.
The maximum sampling rate of the ADC128S052 is 50 kSPS (kilosamples per second). However, the actual sampling rate may be limited by the clock frequency and the conversion time.