The recommended input impedance is 1 kΩ to 10 kΩ to ensure proper operation and minimize signal attenuation.
The ADC128S022CIMT requires an external clock signal, which can be provided through the CLKIN pin. The recommended clock frequency is between 1 MHz and 50 MHz.
The REFBUF pin is an output pin that provides a buffered reference voltage (VREF) for external circuitry. It can be used to provide a stable reference voltage for other components in the system.
The ADC128S022CIMT can operate in either single-ended or differential mode, which is configured through the MODE pin. A logic high on the MODE pin selects single-ended mode, while a logic low selects differential mode.
The maximum throughput of the ADC128S022CIMT is 500 kSPS. To optimize throughput, ensure that the clock frequency is set to the maximum recommended value (50 MHz), and use the fastest available conversion mode (single-ended mode).