The recommended operating temperature range for the ACPL-074L-000E is -40°C to 100°C.
To ensure reliable operation in high-temperature environments, it is recommended to derate the device's current handling capability and to provide adequate heat sinking.
The maximum allowable voltage for the ACPL-074L-000E is 5.5V.
The correct current-limiting resistor for the ACPL-074L-000E can be chosen by considering the LED forward voltage, the desired LED current, and the power supply voltage.
The typical propagation delay time for the ACPL-074L-000E is 10 μs.