The recommended operating voltage range for the 74V1G125CTR is 1.65V to 5.5V, as specified in the datasheet. However, it's essential to note that the device can tolerate a voltage range of 1.4V to 5.5V, but the performance may vary.
To ensure the 74V1G125CTR is properly powered, make sure to decouple the power supply with a 0.1uF ceramic capacitor and a 10uF electrolytic capacitor in parallel, as close to the device as possible. This will help to reduce noise and ensure stable operation.
The 74V1G125CTR can sink or source up to 32mA of current per output, as specified in the datasheet. However, it's essential to consider the total current consumption and ensure that it does not exceed the maximum rating to avoid overheating or damage to the device.
Input signals to the 74V1G125CTR should be clean and free from noise. It's recommended to use a series resistor and a capacitor to filter out any high-frequency noise. Additionally, ensure that the input signals are within the specified voltage range and do not exceed the maximum rating.
The propagation delay of the 74V1G125CTR varies depending on the operating voltage and temperature. At 1.8V and 25°C, the typical propagation delay is around 2.5ns. However, it's essential to consult the datasheet for more detailed information and to consider the specific application requirements.