The recommended operating voltage range for the 74HC74DB,112 is 2.0 V to 6.0 V, with a typical voltage of 5.0 V.
It is recommended to power up the VCC pin first, followed by the input signals, and power down the input signals first, followed by the VCC pin to prevent latch-up or damage to the device.
The maximum frequency of operation for the 74HC74DB,112 is 100 MHz, but this can vary depending on the specific application and operating conditions.
It is recommended to use a 0.1 μF to 1 μF decoupling capacitor between the VCC pin and GND pin, as close to the device as possible, to filter out noise and ensure stable operation.
The maximum current that the 74HC74DB,112 can sink or source is 25 mA per output pin, but this can vary depending on the specific application and operating conditions.