The recommended operating voltage range for the 74HC2G14GW,125 is 2.0 V to 5.5 V.
To ensure proper operation, it is recommended to use a 0.1 μF decoupling capacitor between VCC and GND, and to power the device with a stable voltage source.
The maximum frequency of operation for the 74HC2G14GW,125 is 100 MHz.
The 74HC2G14GW,125 has a maximum junction temperature of 150°C. Ensure proper heat dissipation and avoid overheating to prevent device damage.
The 74HC2G14GW,125 has an ESD protection level of 2 kV according to the Human Body Model (HBM) and 150 V according to the Machine Model (MM).